Certificate of Conformance

Details

Date : 18th August 2005 Type : RS II - Tacky
Length : 12" Batch No : L260105 / L270705
Customer : Labotec Japan Size : X-Large


Objective :

To check the cleanliness of outgoing Latex Gloves.


Result :

Lot No Lot Size Liquid Particle
count (0.5-20um)
Chloride Test
Specification (K) < 500 count / cm2 < 2.00ppm
1 2 3 Average 1 2 3 Average Chloride , C1 (ppm )
Cut 5*5cm ,
soak in 10ml D.I water
oven - 2 hours ( 38 0C )
CTLXL 692 6k XL 356 344 392 364 1.543 1.389 1.426 1.453
CTLXL 691 4k XL 407 368 399 391 1.368 1.451 1.439 1.419
CTLXL 693 9k XL 356 397 422 392 1.213 1.389 1.167 1.256
CTLXL 673 3k XL 415 387 362 388 1.563 1.627 1.498 1.563
CTLXL 682 1k XL 395 287 299 327 1.389 1.577 1.462 1.476

Physical Test Result :

@ Range Specification
Glove Length : 290 - 297 Min 290 mm
Glove Width : 114 - 117 X-Large ( 115+ 5mm)
     
Tensile Strength : 24 - 27 > 14.0
Elongation (%) : 765 - 855 > 700
Visible Hole : 0 / 50 < 4 / 50 (S4 AQL 2.5)
Visible @ @
Contamination : 0 / 50 < 6 / 50 (S4 AQL 4.0)

FRICTION TEST RESULT

Lot No EXTERNAL SURFACE
1 2 3 Average
CTLXL 692 0.36810 0.59870 0.46920 0.47867
CTLXL 691 0.65360 0.48970 0.65540 0.59957
CTLXL 693 0.51360 0.48790 0.54620 0.51590
CTLXL 673 0.64780 0.59860 0.63250 0.62630
CTLXL 682 0.36840 0.58940 0.63580 0.53120


Conclusion : The Latex glove under Batch No : L260105 / L270705 passed the above specification .